Analysis Kits (Chips and Reagents) Experion Automated Electrophoresis — Sample Types What types of samples can the Experion separate and analyze? Experion Automated Electrophoresis — Analysis Kit Ordering Options What are the various analysis kits available for the Experion system? Whatordering configurations are available for these analysis kits? Experion Automated Electrophoresis — Consumables What consumables will be sold separately for the Experion system? Experion Automated Electrophoresis — Dynamic Range of Detection What is the dynamic range of detection for the Experion system? Whatconcentrations of proteins can be separated and detected with the ExperionPro260 analysis kit? What levels of RNA can be detected with the RNA HighSensand StdSens analysis kits? Experion Automated Electrophoresis — Sensitivity of Detection What are the limits of protein and RNA detection with the Experion system? Experion Automated Electrophoresis — Sample Volumes How much protein or RNA is required to run the Experion system? What sample volumes are required for the Experion Pro260, RNA HighSens, and RNA StdSens microfluidic chips? Experion Automated Electrophoresis — Minimum and Maximum Volumes in Chip Wells. What are the minimum and maximum volumes that the sample and gel wells on Experion chips can hold? Experion Automated Electrophoresis — Shelf Life of Chips and Reagents What is the shelf life of the chips and reagents in the Experion Pro260, RNA HighSens, and RNA StdSens analysis kits? Experion Automated Electrophoresis — Storage Temperature for Chips and Reagents At what temperatures should the chips and reagents in the Experion Pro260, RNA HighSens, and RNA StdSens analysis kits be stored? Electrophoresis, Priming, and Vortex Stations Experion Automated Electrophoresis — Time Required for Chip Priming How long does it take to prime a chip for the Experion system? |
Experion Automated Electrophoresis — Number of Samples per Chip How many samples can be run per chip on the Experion system? Experion Automated Electrophoresis — Run Time How long does it take to run a chip on the Experion system? Experion Automated Electrophoresis — Automated Steps What steps of the electrophoresis process does the Experion system automate? Experion Automated Electrophoresis — Detection Method How are samples labeled in the Experion system? How are they detected? Experion Automated Electrophoresis — Sample Labeling Process and Molecular Weight Determination In the Experion system, how are protein and RNA samples labeled with dye? Does this labeling process affect the apparent size of proteins and protein MW determinations? Experion Automated Electrophoresis — Additional Equipment Required What additional equipment/supplies are required to run the Experion system, aside from the Experion instrument and analysis kit? Software Experion Automated Electrophoresis — Software Calculations What calculations are performed automatically by Experion software? Experion Automated Electrophoresis — Data Display, General How does Experion software display separation data? Experion Automated Electrophoresis — Data Display, Simulated Gel View What is the simulated gel view that is displayed by Experion software? Experion Automated Electrophoresis — Data Display, Results of Calculations How are the results of calculations displayed by Experion software? |
→如果您认为本词条还有待完善,请 编辑词条
上一篇有关硅烷化试剂使用中的注意事项 下一篇如何选择层析方法
词条内容仅供参考,如果您需要解决具体问题
(尤其在法律、医学等领域),建议您咨询相关领域专业人士。
0